DMU-03

DMG MORI DMU 50 (3rd Generation) · Siemens SINUMERIK ONE · Bay 1 · Cell C · s/n DMU50-22211

Tool changeAll machines
Live machine view
Five-axis cycle
X/Y/Z, the swivelling B trunnion and the C rotary table follow live telemetry; the door opens when the machine stops. Drag to rotate, scroll to zoom.
Tool change
Effectiveness
OEE this shift
Early (06:00–14:00) · 246 of 283 min running
64%

Availability

87.0%

Performance

74.7%

Quality

97.9%

Current job
WO-24117
Valve block · BH-9021-D

Pieces

6 / 20

Cycle time

6m 35s

This piece

0s elapsed

Operator

Sandro Pereira

Tool

T22 · Ø20 shell mill

Tool life left

18%

Finishes

—

Losses
Downtime by reason
36.9 minutes lost this shift, biggest first.

Setup / first-off

13.4 min

Tool change

8.1 min

No material

5.0 min

Breakdown

4.3 min

Waiting QA

3.8 min

No operator

2.2 min

Quality
Pieces this shift
Ideal 228 s versus actual 305 s per piece.

Good

47

Scrap

1

Rework

0

OEE per hour · %

Queue
Jobs on this machine (3)
The job on the spindle and everything queued behind it, earliest due date first.

WO-24117

Brunner Hydraulik · BH-9021-D OP30 · Al 6082 · setup 46 min

Late

6/20 · due 16 Nov 21:42

WO-24121

Sandvik Tooling · ST-3390-A OP20 · H13 tool steel · setup 35 min

Queued

0/20 · due 18 Nov 21:42

WO-24125

Hot

Helvetica Medtech · HM-2208-C OP10 · 316L stainless · setup 86 min

Queued

0/12 · due 19 Nov 21:42

Readings
Live telemetry
Polled every 5 seconds · spindle 14,433 h, service in 165 h

Spindle load

0 %

Spindle speed

0 rpm

Feed rate

0 mm/min

Spindle temp

21 °C

Coolant temp

20.3 °C

Coolant pressure

0 bar

Vibration

0 mm/s

Axis load B

0 %

Axis positions

X

0.0

Y

0.0

Z

0.0

B

0.0

C

0.0

Spindle history
Spindle load, speed and vibration

Spindle load · %

Spindle speed · rpm

Vibration · mm/s

Alarms
Alarms (8)

Door interlock opened during cycle

Alarm 6621 · 11-17 09:30

High

B axis drive temperature high

Alarm 1105 · 11-17 08:39

Medium

Tool life expired on T7, change required

Alarm 2019 · 11-17 08:18

Low

Tool life expired on T7, change required

Alarm 2019 · 11-16 08:43

High

C axis following error

Alarm 1188 · 11-15 23:48

Medium

Coolant level low in the tank

Alarm 7014 · 11-15 19:08

High

Coolant level low in the tank

Alarm 7014 · 11-15 18:21

High

Coolant level low in the tank

Alarm 7014 · 11-15 14:26

High