Andévalo Híbrido

Needs attention

Andalusia · Wind + solar + storage · 73 MW installed · 9 technicians · manager Darragh Grealish

Output now

13.6 MW

Load factor

19 %

Energy today

135 MWh

Availability

96.6 %

Producing

21 / 26

Open alarms

6

Generation
Last 12 hours
Wind, solar and battery power at the point of interconnection. A charging battery shows below zero.
Conditions
Resource and grid

Wind

8.8 m/s WSW

Irradiance

437 W/m²

Temperature

24.3 °C

Cloud cover

18 %

Conditions

Sunny intervals

Substation

Puebla SE 400 kV

Voltage

399.0 kV

Frequency

50.018 Hz

Power factor

0.992

Curtailment

0 %

Day-ahead price

99.12 €/MWh

Assets

26 assets on site. Open one for its live 3D view.

Power flow

Wind turbine

WTG-01

Siemens Gamesa SG 6.6-170 · 5.0 MW

Producing
1%

Output

0.05 MW

Today

12.4 MWh

Wind

4.6 m/s

Wind turbine

WTG-02

Siemens Gamesa SG 5.0-145 · 5.0 MW

Standby
0%

Output

0.00 MW

Today

15.6 MWh

Wind

7.3 m/s

Wind turbine

WTG-03

Nordex N163/5.X · 6.2 MW

Producing
67%

Output

4.18 MW

Today

17.9 MWh

Wind

10.6 m/s

Wind turbine

WTG-04

Nordex N149/4.0-4.5 · 5.0 MW

Producing
62%

Output

3.11 MW

Today

16.1 MWh

Wind

10.6 m/s

Wind turbine

WTG-05

Nordex N163/5.X · 5.0 MW

Producing
39%

Output

1.97 MW

Today

14.3 MWh

Wind

9.3 m/s

Wind turbine

WTG-06

Vestas V162-6.2 · 5.0 MW

Producing
1%

Output

0.03 MW

Today

13.6 MWh

Wind

4.3 m/s

Wind turbine

WTG-07

Vestas V162-6.2 · 5.0 MW

Fault
0%

Output

0.00 MW

Today

6.5 MWh

Wind

8.6 m/s

Wind turbine

WTG-08

Siemens Gamesa SG 5.0-145 · 6.2 MW

Producing
20%

Output

1.25 MW

Today

21.1 MWh

Wind

7.9 m/s

Tracker block

PV-01

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
38%

Output

1.50 MW

Today

2.1 MWh

Availability

94.4 %

Tracker block

PV-02

Array Technologies DuraTrack HZ v3 · 4.0 MWp

Producing
44%

Output

1.74 MW

Today

2.4 MWh

Availability

97.3 %

Tracker block

PV-03

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
37%

Output

0.90 MW

Today

1.2 MWh

Availability

96.6 %

Tracker block

PV-04

Array Technologies DuraTrack HZ v3 · 2.4 MWp

Producing
27%

Output

0.64 MW

Today

1.3 MWh

Availability

99.0 %

Tracker block

PV-05

Soltec SF7 · 3.2 MWp

Producing
20%

Output

0.65 MW

Today

1.8 MWh

Availability

94.9 %

Tracker block

PV-06

Soltec SF7 · 3.2 MWp

Producing
29%

Output

0.93 MW

Today

1.8 MWh

Availability

97.3 %

Tracker block

PV-07

Nextracker NX Horizon · 3.2 MWp

Producing
34%

Output

1.10 MW

Today

2.2 MWh

Availability

93.9 %

Tracker block

PV-08

Nextracker NX Horizon · 2.4 MWp

Producing
23%

Output

0.54 MW

Today

1.5 MWh

Availability

97.4 %

Tracker block

PV-09

Array Technologies DuraTrack HZ v3 · 3.2 MWp

Producing
28%

Output

0.89 MW

Today

1.8 MWh

Availability

94.7 %

Tracker block

PV-10

Nextracker NX Horizon · 2.4 MWp

Standby
0%

Output

0.00 MW

Today

1.4 MWh

Availability

98.5 %

Inverter skid

INV-01

SMA Sunny Central 4600 UP · 3.1 MVA

Producing
11%

Output

0.35 MW

Today

5.5 MWh

Availability

97.2 %

Inverter skid

INV-02

Huawei SUN2000-215KTL · 4.6 MVA

Standby
0%

Output

0.00 MW

Today

4.8 MWh

Availability

97.0 %

Inverter skid

INV-03

Sungrow SG3125HV-MV · 3.1 MVA

Producing
36%

Output

1.12 MW

Today

5.6 MWh

Availability

96.6 %

Inverter skid

INV-04

Sungrow SG3125HV-MV · 5.0 MVA

Producing
24%

Output

1.18 MW

Today

7.2 MWh

Availability

95.4 %

Inverter skid

INV-05

Huawei SUN2000-215KTL · 4.6 MVA

Producing
25%

Output

1.14 MW

Today

6.2 MWh

Availability

98.3 %

Inverter skid

INV-06

Huawei SUN2000-215KTL · 3.1 MVA

Maintenance
0%

Output

0.00 MW

Today

4.0 MWh

Availability

98.5 %

Battery container

BESS-01

Tesla Megapack 2XL · 5.0 MW

Producing
60%

Output

3.00 MW

Today

0.0 MWh

State of charge

44 %

Battery container

BESS-02

CATL EnerOne+ · 3.9 MW

Producing
73%

Output

2.85 MW

Today

0.0 MWh

State of charge

44 %

Alarms
Site alarms
Most recent events from this site's assets.

Service interval exceeded

WTG-05· 11-17 06:12
Medium

Soiling loss above threshold

PV-05· 11-17 05:40
Medium

Blade ice detected

WTG-07· 11-17 02:43
High

Soiling loss above threshold

PV-08· 11-17 01:02
Low

IGBT temperature high

INV-06· 11-16 17:18
Medium

Row stowed – high wind

PV-06· 11-16 15:06
Medium